Panel Kawalan Kuasa SCR HYP-S Series product image

Temperature Control Panels

Panel Kawalan Kuasa SCR

HYP-S Series / SCR Power Control Panel

Kawalan sudut fasa atau lintasan sifar dengan keluaran boleh dilaras berterusan, mengurangkan arus masuk grid dan turun naik suhu.

Power Range
10 – 400 kW
Temperature Range
Controlled object ≤ 1000°C
Power Supply
380V / 415V, 3-phase

Parameters shown are typical ranges and can be adjusted to your process. Lead time and custom options are confirmed in the technical agreement.

Gambaran Keseluruhan Produk

Large heating circuits using contactor on/off control see inrush of 6–8× rated current, and frequent switching shortens contact life. The SCR cabinet replaces contactors with anti-parallel thyristors, continuously regulating output by phase-angle or zero-crossing control—current rises smoothly and temperature accuracy reaches ±0.5°C.

Phase-angle responds fast but generates harmonics, suiting smaller loads or harmonic-tolerant sites; zero-crossing switches by whole cycles with minimal harmonics, ideal for large resistive loads. The cabinet has fast fuses, RC snubbers, and cooling fans; thyristors mount on aluminum heat sinks with forced air triggered above 75°C.

Control signals support 4–20 mA, 0–10 V, and RS485 Modbus. Multi-zone control regulates each loop independently to avoid interaction. Enclosure is IP54, with optional dust filter for dusty sites; for explosion protection use pressurized purging or flameproof construction.

Ciri-ciri Pembinaan

  • Phase-angle / zero-crossing selectable, continuous output
  • Smooth inrush, less grid impact
  • Temperature accuracy up to ±0.5°C
  • Fast fuse + RC snubber protect thyristors
  • Supports 4–20 mA, 0–10 V, RS485 Modbus
  • Independent multi-zone control, 1 – 12 loops

Spesifikasi Teknikal

Panel Kawalan Kuasa SCR technical specifications
Control Power10 – 400 kW
Rated Voltage380V / 415V, 3-phase
Control ModePhase-angle / zero-crossing control
Control Signal4–20 mA / 0–10 V / RS485
Control Accuracy±0.5°C
CoolingForced air (triggered ≥75°C)
ProtectionIP54 (upgradeable to IP65)
Loops1 – 12 loops

The table lists typical configuration ranges. Special pressure, temperature or media conditions require re-checking; final parameters are confirmed by the approved drawings and technical agreement.

Aplikasi Biasa

  • Thermal-oil boiler power control
  • Duct heater continuous control
  • Laboratory electric furnaces
  • Multi-zone mold control
  • High-power ovens

Maklumat Diperlukan untuk Pemilihan

  • Medium name, concentration, and whether it contains particles
  • Total medium volume or circulation flow rate
  • Initial and target temperature
  • Required heat-up time
  • Vessel or pipe size and material
  • Supply voltage, phases, and available capacity
  • Installation environment and hazardous-area requirements
  • Connection standard and mounting orientation